< img height="1" width="1" style="display:none;" alt="" src="https://px.ads.linkedin.com/collect/?pid=5785916&fmt=gif" />
loading

KingKonree - Solid Surface Manufacturer of Sanitary Ware, Solid Surface Countertops & Sheets for over 24 years, innovation in moulding and thermoforming

 

Hezheng Sanitary Ware: Summary of common faults and solutions of toilet flushing function

by:KingKonree     2021-09-30
Hezheng Sanitary Ware: Common faults of toilet flushing function and solutions. Recently, I have been busy with new products. Yes, Hezheng will launch new products soon! It is very worth looking forward to, so be sure to pay attention to it at all times! The second highest usage rate of smart toilets is definitely the cleaning function. Unisex buttocks washing, women's washing care for women's health, mobile washing makes washing more comprehensive and hygienic. Not only that, the momentum of the water column can promote blood circulation in the buttocks and reduce constipation and hemorrhoids. It is really a very friendly and exciting product. No wonder some people say that as long as you don't use the flushing function of the toilet for a day, you feel bad for the whole person. The softness of the rinse is too hard to extricate yourself! So, what are the most common problems we encounter with regard to flushing? No water from the nozzle? Does the nozzle have a small amount of water? The nozzle is leaking? Can't the nozzle come out? Don't worry, let's talk about all of these today! 01. No water from the nozzle No water from the nozzle. First of all, you must confirm whether the water is cut off at home. If the water is cut off at home, water will definitely not come out! Angle valve closed: Whether the angle valve connected to the water inlet pipe has been closed unintentionally. When the angle valve is closed, water can't get in, not only can't flush, but also can't flush. Blockage of the water inlet pipe: When the water inlet pipe was removed for cleaning and cleaning, something accidentally got into the pipe, which caused the pipe to be blocked and water could not get in. You can use a piece of iron wire to reach into the pipe and try to poke it. If there is a foreign body, the part of the end of the water inlet pipe connected to the toilet can also be separated to clean the foreign body, or the pipe can be replaced directly. It is best to find professionals to disassemble the pipe to avoid losses due to unskilled techniques. Internal component failure (Professional assistance is required): If the problem is still not solved after the above reasons are checked, it may be that the internal water flow control component is malfunctioning (it is like a faucet switch is broken, and the command issued by the owner is not Way to implement). In this case, you need to contact the merchant or manufacturer, ask them to check the problems encountered, and then solve them. Non-professionals, do not do it yourself to avoid damage to the toilet. For the new retro series HZ70202, the reason for the small water output of the nozzle is very similar to the reason why the nozzle does not output water. If the water flow is small, you can measure the size of your own water flow by yourself. If you don’t know how to measure it, you can click here: Water pressure measurement method. The reason for the low water flow can be viewed directly here: Special Feature ︱ The toilet flushes, the water flow is low, and there is no energy? Look here.... I won't repeat them here. The angle valve switch reduces the water flow. Turning the angle valve switch connected to the water inlet pipe reduces the water inadvertently. As the water flow decreases, so does the flushing water flow. The water quality of the filter screen at the inlet pipe of the new retro series HZ702 is different. The water quality is different in different areas, especially in the northern area, where there is more scale. After a period of use, the filter at the inlet has too much scale, resulting in a decrease in water flow. The filter can be taken out and cleaned! The flushing water pressure is adjusted down. The flushing water pressure can be adjusted in 4 levels. When the water pressure is adjusted lower, the impact force is not so great. It feels as if the water flow is reduced. You can use the remote control to adjust the water pressure. . 03. The nozzle is leaking and the nozzle is self-cleaning for health and hygiene. Before the nozzle comes out, it will discharge water by itself to flush the nozzle; after use, it will also discharge water to flush the nozzle. this is normal phenomenon. The internal components (solenoid valve) are faulty. Because of the water quality or the relatively large dust in the environment, the internal components (mainly the solenoid valve) are attached to the magazine and malfunction, and the water keeps dripping. You can contact the merchant or manufacturer and ask them to assist in the solution. 04. The nozzle can't come out, whether the human body is seated or not. The program design (to prevent accidental collision): If the human body is not seated on the toilet, even if the cleaning button is pressed, the nozzle will not extend for cleaning. In this state, the program defaults to no one Use is caused by human touch. New Retro Series HZ702 Seat Seating Sensing Failure A. Seating Sensing Device Failure When the seating sensing device on the seat is malfunctioning, a person sits on it and the toilet does not respond. Therefore, when the cleaning button is pressed, the cleaning function does not operate due to the program's anti-inadvertent touch design. You can contact the merchant or manufacturer for assistance. B. The human body does not touch the seat-sensing position due to various reasons. When a person is sitting down, the seat-sensing position is not touched. Therefore, the seat-sensing device does not respond. The standard sitting posture can be used to re-seating in the right position so that the human body touches the seat point. Mechanical failure of the nozzle The so-called mechanical failure is that the nozzle is stuck, making it impossible to extend the nozzle. You can contact the merchant or manufacturer for assistance. Do not pull out the nozzle by force. The main control board method causes the main control board to fail, and the program cannot be run. Please contact the merchant or manufacturer for assistance. (
Custom message
暂无友情链接数据
Chat Online 编辑模式下无法使用
Leave Your Message inputting...